Measures the noise levels and frequencies on telecom, power and grounding lines
- Easily view the noise current level in each band
- Record noise level variations over time in each band
- Measures noise current on earth lines easily
- Hard to detect One-Shot noise with a spectrum analyzer or oscilloscope, are reliably captured
- Data can be automatically saved to a PC Card, continuous long-term recording
| Basic specifications (Accuracy guaranteed for 1 year) |
 |
| Input terminal |
BNC (max. input voltage 5V peak), 5kHz to 100MHz (-3dB) |
| Measurement ranges |
[Current] 0.2mA, 2A, 20A (used with the 9754)
[Voltage] 10mV, 100mV, 1V |
| Band Path Filter characteristics |
Center frequency: 15k, 70k, 250k, 1M, 5M, 20M, 60MHz, 7 BPFs separates noise (fixed), measuring the peak value in each band |
| Monitor function |
Displays real-time peak-to-peak values in each frequency band on level meters, Refresh interval: 100ms |
| Logging function |
Records maximum peak-to-peak values in each frequency band at the specified recording interval to internal memory (16 days at 1sec interval to 2.5 years at 60sec interval) |
| Recording interval |
1, 2, 5, 10, 20, 30, 60 sec |
| Functions |
Displays a time-series graph, Alarm function, Event mark function, External trigger |
| Interface |
LAN, RS-232C |
| Power consumption |
AC ADAPTER 9418-15 /30VA max., BATTERY PACK 9447 /Continuous use 1hour (20VA max,) |
| Dimensions and mass |
203 (7.99in) W × 170 (6.69in) H × 52 (2.05in) D mm, 1.2kg (42.3oz) |
| Supplied accessories |
AC ADAPTER 9418-15 × 1, Carrying case × 1, Strap × 1, Ferrite clamp × 3, CD-R (DATA VIEWER for 3145 software, Communication commands manual, or other) × 1, Operating manual × 1, Operating guide × 1 |
|
|
|
|