Hioki Model 3290
 $749.95 

All the Functions You Need for Measurement at DC or 1Hz and Up

  • Choice of three sensors (Example combinations)
  • 3290+9691 : Measure up to 100A
  • 3290+9692 : Measure up to 200A
  • 3290+9693 : Measure up to 2000A
  • Choice of measurement methods
  • DC (for battery measurement)
  • AC+DC RMS (for full-/half-wave rectification measurement)
  • AC RMS (for current distortion measurement)
  • PEAK (for peak value measurement) of inrush current, etc.)
  • Choice of output (Simultaneous output)
  • Effective value output, frequency output, waveform output
Basic specifications (Accuracy guaranteed for 1 year)
3290 3290-10
Measurement method DC, AC+DC (True RMS), AC (True RMS/ Average rectified) DC, AC+DC (True RMS), AC (True RMS)
Peak value display Absolute value (of waveform peak) Polarities independently (±peak value of waveform, in DC mode)
Separate AC from DC output Separate constituent element of AC, DC None
Output (terminal 1) Current waveform or true RMS value (2 V / setting range), Frequency value (1 VDC / setting range) Current waveform or true RMS value (2 V / setting range)
Output (terminal 2) Rms current/Low-battery warning switch Current integral value (1 VDC / setting range)
Integral current measurement None ±, +, - integral, average value
Rate measurement None Operating time rate, total measurement time
Timer settings None 99 hr, 59 min. (for repeated up to 20 times)
Data storage None Peak, integral value, operating time rate, or other
Basic accuracy at DC current 20.00/ 100.0A (using the 9691 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
20.00/ 200.0A (using the 9692 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
200.0/ 2000A (using the 9693 sensor): ±1.8 % rdg. ±1.0 A/ ±5 A
Basic accuracy at AC current
(45 to 66 Hz)
20.00/ 100.0A (using the 9691 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
20.00/ 200.0A (using the 9692 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
200.0/ 2000A (using the 9693 sensor): ±1.3 % rdg. ±0.8 A/ ±3 A
Voltage measurement None
Frequency measurement 1.00Hz to 1000Hz, Basic accuracy: ±0.3% rdg. ±1dgt.
Crest factor 2.5 or later, or rated peak value of sensor
Frequency characteristic DC, or 1 Hz to 1 kHz (accuracy guaranteed range)
At monitor output: based on the using sensor
Other functions Selectable of responce time, filter (fc=550 Hz)
Power supply LR6 (AA) alkaline batteries × 4, Continuous use : 22 hr, or AC adapter 9445-02/-03 (The 3290-10 only: external power supply possible)
Dimensions, mass 155 mm (6.10 in) W × 98 mm (3.86 in) H × 47 mm (1.85 in) D, 545 g (19.2 oz)
Supplied accessories Carrying strap ×1, LR6 (AA) alkaline batteries × 4
Hioki AC/DC Clamp On HiTester (TRMS)
Qty:
Shopping Cart more
0 items
Manuf. Info
Hioki
Main Hioki page
All Hioki products
Notifications more
Notifications
Notify me of updates to AC/DC Clamp On HiTester (TRMS)
Information
Request a Quote
Returns & Shipping
Privacy Notice
Conditions of Use
Credit Application
Contact Us